Research

CPT Prototype: 16 hours of clock data

CPT Prototype: 16 hours of clock data

Our first rubidium-87 atomic clock successfully demonstrates improved frequency stability over a free-running crystal oscillator. In a 16-hour continuous run, it achieved up to 70× better stability, marking an important milestone in our atomic clock development.

Research


Our first atomic clock, built using the principle of Coherent Population Trapping (CPT) based on rubidium-87, locks its crystal oscillator to the ground-state hyperfine transition of ⁸⁷Rb at 6.834 GHz. That frequency is the same in every ⁸⁷Rb atom, which makes it a very stable reference.

We ran our clock continuously for just over 16 hours and compared it with the free-running crystal oscillator that it disciplines.

The Allan deviation of the disciplined oscillator (Fig. 1) is 2.4×10⁻¹⁰ at 1 s. It falls to 1.2×10⁻¹¹ at 100 s and bottoms out near 150 s. The atomic clock beats the free-running crystal at every averaging time. The gap is ~ 7 times at 1 s and grows to ~ 70 times near 400 s, where the crystal is at its least stable.

Fig. 1: Allan deviation of the free-running and Rb-disciplined crystal oscillator.

Fig. 2 shows the same run in the time domain as 100 s frequency averages. Over the run, the free-running crystal (orange) wanders across more than 2 parts in 10⁸, and its path is too irregular to predict or correct.

Fig. 2: Fractional frequency over 16 hours, 100 s means with the median subtracted.

The disciplined oscillator (blue) stays on the zero line. This shows that the feedback loop is holding the crystal to the 6.834 GHz ground-state hyperfine transition of ⁸⁷Rb. The disciplined oscillator still drifts slowly, by less than 1 part in 10⁹ over 16 hours, and this drift is what makes its Allan deviation rise beyond 1000 s.

Bringing it down is the next thing we are working on.